products

Cold Water Tank Ballcock , Toilet Valve Float Lever / Thread Connection Type

Basic Information
Place of Origin: China
Brand Name: Sanlo
Certification: ISO9000
Model Number: customize
Minimum Order Quantity: 500
Price: negotiable
Packaging Details: Box
Delivery Time: 10-30days
Payment Terms: Western Union, T/T
Detail Information
Color: Polishing Material: 304/316L
Connection Type: Lever / Thread Delivery Time: 10-30days
Pressure: Normal Pressure
High Light:

ballcock float ball

,

toilet valve float


Product Description

                   Customize Round Float Ball Polishing Fixed Float Bracket For Valve

 

 

Video: https://youtu.be/lTT3v90H_1g

 

 

The reason why argon arc welding can obtain such a wide range of applications is mainly because of the following advantages.

 

1. The electrode loss is small, the arc length is easy to maintain, and there is no flux or coating layer during welding, so it is easy to realize mechanization and automation;

 

2, argon arc welding can weld almost all metals, especially some refractory metals, easily oxidized metals, such as magnesium, titanium, molybdenum, zirconium, aluminum and other alloys;

 

3. It is not limited by the position of the weldment, and it can be welded at all positions.

 

 

Technical Parameters:

 

Dimensions ΦA Material Thickness(mm) Pressure(Mpa) Morphology Connection Type
Φ60 304/316L 0.7 1.6 Character/Polishing Leve/Thread
Φ70 304/316L 0.8 1.6 Character/Polishing
Φ75 304/316L 0.8 1.6 Character/Polishing

 

 

Competitive Advantage:

 

In the oxidation ditch sewage treatment plant, the detector for dissolved oxygen measurement is easily contaminated, so it requires frequent cleaning, which makes it expensive. The use of a float-type bracket solution can greatly reduce sensor maintenance. After installing the float-type bracket in the detector, the DO402 dissolved oxygen analyzer system was field tested and found that there was no serious dirt accumulation in the sensor, which reduced maintenance work and enabled long-term, continuous measurement.

 

 

Maintenance should consist of inspection to see that the float is free to move and coated with any substance , which would change its weight or volume significantly. IF this occurs, this float should be cleaned .This is easily accomplished without disturbing the installation . In addition , the stem may be wiped down to remove any buildup.The only repair possible in the field is replacement of either the float or stem . Dents or nicks on the float are usually of no consequence to operation.

 

Contact Details